GE OEC Elite CFD C-arm
- Completely Refurbished
- Sixth Generation OEC C-Arm System
- GE OEC C-Arms Are The Industry Standard Which All Other Systems Are Compared To
- Rotating Anode X-Ray Tube
- 1K x 1K Image Resolution
- Digital CCD Camera
- 32″ LED Lit Flat Panel Monitor
- 21cm and 31c Flat Detector Options
Description
OEC Elite CFD C-arm Specifications
C-arm X-Ray System:
Generator:
- 60kHz high frequency
- 15kW power
- Up to 120kVp
- Up to 75mA for radiographic film exposure
- Continuous high level fluoro (HLF) up to 20mA
- Digital spot up to 75mA
- Pulsed HLF up to 40mA
- Full power from standard wall outlet
- Patented battery buffered design
X-Ray Tube:
- Rotating anode X-ray tube
- 0.3mm and 0.6mm focal spots
- Anode heat capacity: 300,000 HU
- Anode cooling rate: 85,000 HU/min.
- Housing heat capacity: 1,600,000 HU
- Housing cooling: -9″ II = 22,500 HU/min, 12″ II = 22,500 HU/min
Digital Image Orientation:
- Digitally adjusts image display for live and last image hold
- Automatic image update preserves image orientation settings applied during live and last image hold subsequent images
– Image rotation
– Image reversal (side-to-side)
– Image invert (top-to-bottom) - On-screen orientation indicator
- Fully digital with precise 1 degree rotation increments
PreView™ Collimator:
- On-screen collimator position indication
- PreView™ iris collimator
- PreView™ Tungsten rotatable double leaf collimator
- Adjusts collimators without X-ray exposure
Fluoro Mode:
- kVp range: 40 -120
- mA range: 0.2 – 10 normal mode 0.2 – 20 HLF (high level fluoro)
- Auto and manual fluoro modes
Pulsed Fluoro Mode:
- kVp range: 40 – 120
- mA range: 0.2 – 10 normal mode, 0.2-40 HLF
- Pulse rate: 8 pps
- Pulse width: 25 ms
- Auto and manual pulsed fluoroscopy modes
- Reduces x-ray dose to patient and operator
Digital Spot Mode:
- kVp range: 40 – 120
- mA range: Up to 75
- Automatic exposure termination and automatic image save
Video Imaging System:
21 cm CMOS Flat Panel Detector (CFD):
- Tri-mode 21 cm/15 cm/11 cm
- Minimum central resolution (at display):
– 21 cm: 2.5 lp/mm
– 15 cm: 3.0 lp/mm
– 11 cm: 3.3 lp/mm - Matrix: 1536 x 1496 total pixels
- DQE(0): 72%
- Pixel Pitch: 135.3 μm
- Removable grid with on-screen detection status
31 cm CMOS Flat Panel Detector (CFD):
- Tri-mode 31 cm/21 cm/15 cm
- Minimum central resolution (at display):
– 31 cm: 1.8 lp/mm
– 21 cm: 2.2 lp/mm
– 15 cm: 2.4 lp/mm - Matrix: 1548 x 1524 total pixels
- DQE(0): 72%
- Pixel Pitch: 198.0 μm
- Removable grid with on-screen detection status
AutoTrak™ Automatic Brightness Stabilization (ABS)
- Automatically seeks the subject anatomy anywhere within the imaging field
- Selects the optimum imaging technique by varying mA, kVp, and gain
- Automatically adjusts to anatomical size and location
- Provides uniform image quality throughout the entire image
Image I.Q.:
- Smart Window
– Dynamically senses the collimator position and automatically adjusts brightness and contrast to produce high image quality. - Smart Metal
– Allows user to adjust automatic brightness and contrast sensitivity levels to metal
– Provides optimum image quality even when metal is introduced to the field - Tungsten Collimator
– Denser collimator limits X-ray exposure area
– Reduces scatter radiation
– Improves image detail
C-arm Image Processing:
- 1k x 1k x 16 bit image intensifer
Video Monitor:
- 27 in (69 cm) LCD TFT color display
- Anti-glare
- Monitor mounted on an articulating arm
– 45 in (114 cm) horizontal travel
– 17 in (43.2 cm) vertical travel
– 27 in (68.8 cm) forward travel
– 5° up/5° down tilt
– Display viewable from all four sides of workstation
– Horizontal and vertical viewing angle 170° - 450 cd/m2 maximum brightness
- Touch screen system control
- 2560 x 1440 high resolution display
- Integrated PIP window to display color DVI-D input
Configurations:
ESP (Expanded Surgical Package) Platform:
- >Preset Imaging Profiles
– General
– Orthopedic
– Spine - >Noise filter with on-screen indicator
- Minimal difference spatiotemporal noise filter (MDST)
- Real-time dynamic general purpose range management (GDRM)
- Automatic digital brightness and contrast control
- Manual digital brightness and contrast control
- Negate mode
- Save and auto-save feature
- Swap and auto-swap feature
- Patient information
– Examination list
– Customized patient information - Set-up functions
– Acquisitions
– Image Profile
– DICOM
– Network
– Regional
– Security
– Utilities - Last image hold
- 50,000 image storage
- USB export with DICOM viewer for displaying images on PC platforms
– Full-size or half-size
– Web viewable
– JPEG and BMP
– DICOM compatible
– OEC compatible
– De-identify DICOM images
– Remove patient information - HIPAA SecureView
– Password protection
– Blank screen function
– Delete all patient information - >Zoom and pan function
- Image annotation
- Measurement
– Distance
– Angles
– Percent stenosis - Digital image rotation
Additional Features:
Tech View Monitor:(optional)
- 10.4” (26.4cm) display, LCD flat panel monitor mounted on mainframe
– 270° side/side rotation
– 30° up/ 5° down tilt
– Horizontal viewing angle 80°, Vertical viewing angle 70° - 800 x 600 resolution monitor
Super-C Configuration:
- Adds Larger “C” for increased orbital rotation (145 degrees)
- Increased Arc Depth (33″ / 838mm)
MD Configuration:
- Adds motorized movements of c-arm
Uninterruptible Power:
- Orderly shutdown Electrical
- Input power (60 Hz or 50 Hz) 9900 Elite
– 120V @ 12 A
– 200V, 220V, 230V, 240V @ 10 A
Regulatory Compliance:
- U.S. 21 CFR Subchapter K
- NFPA 99
- UL 60601-A (CSA/NRTL)
- IEC60601-1 (plus relevant collateral and particular standards)