Fluoroscopic C-arm Safety and Radiation Exposure Guidelines

Fluoroscopy Safety

At least 50% of an estimated 4-10 million interventional pain procedures are performed yearly in the U.S. under fluoroscopy using fluoroscopic imaging equipment, such as a Fluoroscopic C-arm. Most clinicians favor fluoroscopy because it allows for a more exact needle placement, which ensures the accurate delivery of the injected drug. However, fluoroscopic guidance as an interventional technique does pose a radiation risk to patients, physicians, and anyone in close proximity. Rest assured, federal regulations place limitations on the maximum output for these C-arms. There are also a variety of techniques and methods for reducing the risk in the private practice setting.

Radiation Exposure: Understanding the Risk

The potential for any patient radiation is a valid and real concern that should be discussed and mitigated. Furthermore, we must always remember that the goal of all interventional radiology procedures is to treat (not harm) patients and improve their overall well-being. As a physician, any radiation risks that come with interventional procedures should be discussed with patients, especially when the possible amount of radiation could be high.

In normal conditions, fluoroscopy delivers roughly 5 rads per minute in the direct beam. The patient’s particular anthropometrics — which is the study of the variances in human sizes and measurements — can greatly determine the exposure rate. Specifically, the thickness of the patient is a variable that is known to greatly affect the exposure rate: the thicker the patient, the higher the exposure. Even small doses of radiation (1 rad = approximately one chance in 100,000) can cause damage to the DNA. The damage to the DNA caused by radiation has been associated with various health problems.

Shielding the patient is not always possible. This means that time and distance become critical in helping reduce the exposure. Time: shorter fluoro times can be achieved when the physician uses intermittent fluoroscopy (as opposed to continuous), and utilizes the image hold capacity. Distance: the patient’s exposure increases exponentially the closer he/she is positioned to the x-ray tube. Positioning the patient as far as possible from the x-ray tube (maybe 12 to 15 inches away from body), and as close as possible to the image intensifier, can lower exposure. (Decreasing x-ray field size can also reduce patient exposure).

With Fluoroscopic C-arms, knowledge and education are a must to properly monitor and reduce exposure levels to your patients and staff. You should receive training from a qualified expert (radiologist or radiological health physicist) on safety procedures and proper imaging techniques to minimize risk and future liability. Good safety practices, such as the ones below, can also keep radiation amounts As Low As Reasonably Achievable (ALARA).

Radiation Safety Guidelines

First and foremost, do not allow any unauthorized visitors during x-ray exams. Only individuals required for the radiographic procedure should be present in the radiographic room during exposures. Time, distance, and shielding are the three basic guides that could and should be taken for radiation safety:

  • Timing. As we mentioned before, with timing, shorter fluoro times can be achieved when the physician uses intermittent fluoroscopy. Also, analyze original radiographs before performing a fluoroscopic examination. Viewing original radiographs, especially for orthopedic studies, can dramatically reduce the repeat rate for the time required for procedures.
  • Distance. Observers should stand on the image intensifier side of the C-arm if possible, to avoid radiation leakage from the x-ray tube. When not assisting, step away from the patient during fluoro, as feasible. Stepping even one foot further back can significantly reduce a person’s dose. These are things to consider when calculating the size of the room for the C-arm.
  • Shielding. In interventional fluoroscopy procedures, the tissue of concern is the skin. The skin that is at the site where radiation enters the body receives the highest dose than any other body tissue. All workers in the x-ray room during studies must have a lead apron, and other appropriate shielding wear.

Guide to Shielding

  • Lead Apron and Thyroid Shields. Verify that the apron is 0.5 mm lead equivalent, and be sure aprons and shields are in good condition (remove any damaged ones). Insist on well-fitting protective gear with a weight your body can handle. Hang aprons and shields on racks. Do not bend or fold them as this can cause cracks and tears in the protective material, making exposed body parts susceptible to radiation.
  • Wrap-around Apron. When wearing lead aprons, it is imperative to keep the lead between you and the x-ray tube. Meaning, do not turn your unshielded back to the x-ray tube. If you do need to move about the room where exposing your back may be likely, insist on using a wrap around style apron.
  • Leaded Eyeglasses. Those who routinely fluoro for long or interventional procedures, lead glasses with side shields can provide additional protection to the lens of the eyes. Remember, you may need to look sideways from the C-arm x-ray tube to see the image on the monitor, which will leave the lens unprotected if glasses do not have side shields.
  • Leaded Gloves. Lead gloves are required if hands are potentially close to or in the primary beam.

Additional Safety Guidelines

  • For needles, try using just one hand so you can keep your other hand away from the needle, and any potential exposure. Be sure there is ample lighting for accuracy. Properly dispose of used needles immediately after use.
  • If possible, structural shielding (such as ceiling-mounted lead acrylic shield and an under-the-table shield) should be implemented.
  • Always check for damages. If the C-arm or fittings are damaged, the x-ray tube and intensifier may become misaligned, resulting in image degradation or loss, as well as presenting a potential injury to the staff and patient.
  • The fluoroscopy beam-on time and x-ray field size should be reduced as much as possible, and the x-ray beam kept well collimated. Failure of the x-ray beam collimation may lead to primary beam x-ray exposure outside of the selected image intensifier input area. This would result in image degradation and additional exposure for the patient.
  • Pulsed fluoroscopy, single pulse fluoroscopy mode, manual mode, fluoroscopy timer warning, and last image hold (“freezing the screen”) are also good safety practices.

For any other used C-arms or refurbished imaging equipment questions please contact one of our sales specialists at 877-283-3154.

Posted in

Aaron O

C-Arm Service Contract

Ongoing service of medical imaging equipment is essential, and it is important to remember that not all service contracts are created equally. There is nothing more frustrating than not being able to provide your C-Arm services because of downtime. Make sure that the place you’re opting for has a reputation for providing efficient services and…

Image Intensifier – Usable Life

An image intensifier is a important component for fluoroscopic equipment such as a C-Arm.  Most image intensifiers have a good lifespan,  however, it is common for fluoroscopy systems to go through a few image intensifiers throughout their life. Following are a few ways users can prolong the life of their image intensifiers and/or determine if…

The Need for Digital Imaging

Analog image intensifiers and digital flat plate detectors have their pros and cons. However, in today’s medical imaging field, digital imaging is the efficient way to go if hospitals, outpatient facilities, and private practices want to stay competitive. Digital images are easily transferred throughout the hospital and other health care facilities. They can be stored…

C-Arm Upgrade

During the pandemic, many elective procedures and normal operations in many imaging departments were put on hold, leading to an increase in cancellation for non-critical exams.  Now, C-Arms will need to be in good working order to meet hospital’s imaging demands. Hospital CEO’s and radiologists are under more pressure than ever to reduce funds without…

Manufacturers and Models for Fluoroscopy and C-Arms

Major manufacturers in the fluoroscopy and mobile C-Arm market are GE Healthcare, Koninklijke Philips N.V., Siemens Healthineers (Siemens AG), Hologic, Inc., and Ziehm Imaging. They are constantly researching and developing their technology to be more effective and cost-effective to strengthen their hold on the market. At Pacific Healthcare Imaging we sell and support new, pre-owned,…

Renting a C-Arm

Renting a C-Arm can be an attainable operating expense that fits into even modest budgets.  For many hospitals, clinics, or private imaging centers, buying a new or used C-Arm requires large capital expenditures. The greatest value of renting is the low risk it carries. It brings the equipment you need into your facility, and costs…

Types of C-Arms

C-arm machines are used for a range of diagnostic imaging and minimally invasive surgical procedures.  They are flexible, and can be used in a variety of situations. C-Arms come in different sizes including Mini C-Arms, Compact C-Arms, Full-Size C-Arms.  Keep in mind there are also modifications for C-arms such as digital retrofit devices for analog…

Site Considerations for C-Arms And Portable X-Ray Machines

Think about space and other requirements for your device’s location. Consider existing floor plans, equipment placement, plumbing, power requirements, shielding, and other safety measures. Pre-Planning will reduce delays and allow for correction of possible problems. At Pacific Healthcare Imaging, we can provide you all the information and help you need for your machine purchase. Power…

How to Perform a Basic C-Arm Diagnosis to Improve Image Quality

Do you have poor image quality on your C-Arm? On older C-Arms, the image intensifier or the x-ray tube may need to be replaced or recalibrated, however sometimes a simple height adjustment of the C-arm can improve the image quality. Make sure the body part is centered to the tube. If the anatomy is below…

OEC 9800 Monitor Upgrade

Available Options: There are currently several aftermarket OEC monitor upgrades: a single, large split screen, two individual screens, fixed screens, rotating screens, screens on an articulating arm. There are also 1k, 2k, and now, 4k resolution. Cost: There is a board range of prices, depending on options.  At the high is including an articulating arm,…